Compatibility Matrix Datasheet

AVIKA2X25050LN1R

50 x 50 mm Street lighting solution Universal EN13201 M class design. Medium roads, where road width is the same or less than the pole height. Optimized for both 3535 & 5050 high-power LED packages Material : Recycled PMMA

Compatibility Matrix

Measured results in black Simulated results in blue
LED Manufacturer LED Reference FWHM 1 FWHM 2 FWTM 1 FWTM 2 LOR Efficacy 1 Efficacy 2 CCI
LUMILEDSLUXEON XR-5050 SQR 2X484.60.4
LUMILEDSLUXEON XR-HL2X84.70.3
PHILIPSFortimo FastFlex 2x2 DA UHE83.30.4
PHILIPSFortimo FastFlex LED 2x2 DA G583.40.3

AVIKA2X25050LN1R with LUMILEDS LUXEON XR-5050 SQR 2X4

Measured results
Beam angle @50% (Deg.) Major axis or Narrow Pos.Beam angle @50% (Deg.) Major axis or Wide Pos.Beam angle @10% (Deg.) Major axis or Narrow Pos.Beam angle @10% (Deg.) Major axis or Wide Pos.Efficacy (cd/lm) Major axis or Narrow Pos.Efficacy (cd/lm) Minor axis or Wide Pos.
0.4
https://www.optic-gaggione.com/wp-content/uploads/led_manufacturer_logo/LUMILEDS/LUMILEDS.jpeg
LUMILEDSLUXEON XR-5050 SQR 2X4
A lengthB heightC foot
50.0(mm)7.0(mm)50.0(mm)
Normalized Intensity
Viewing angle (deg.)

AVIKA2X25050LN1R with LUMILEDS LUXEON XR-HL2X

Measured results
Beam angle @50% (Deg.) Major axis or Narrow Pos.Beam angle @50% (Deg.) Major axis or Wide Pos.Beam angle @10% (Deg.) Major axis or Narrow Pos.Beam angle @10% (Deg.) Major axis or Wide Pos.Efficacy (cd/lm) Major axis or Narrow Pos.Efficacy (cd/lm) Minor axis or Wide Pos.
0.3
https://www.optic-gaggione.com/wp-content/uploads/led_manufacturer_logo/LUMILEDS/LUMILEDS.jpeg
LUMILEDSLUXEON XR-HL2X
A lengthB heightC foot
50.0(mm)7.0(mm)50.0(mm)
Normalized Intensity
Viewing angle (deg.)

AVIKA2X25050LN1R with PHILIPS Fortimo FastFlex 2x2 DA UHE

Measured results
Beam angle @50% (Deg.) Major axis or Narrow Pos.Beam angle @50% (Deg.) Major axis or Wide Pos.Beam angle @10% (Deg.) Major axis or Narrow Pos.Beam angle @10% (Deg.) Major axis or Wide Pos.Efficacy (cd/lm) Major axis or Narrow Pos.Efficacy (cd/lm) Minor axis or Wide Pos.
0.4
https://www.optic-gaggione.com/wp-content/uploads/led_manufacturer_logo/PHILIPS/PHILIPS.jpeg
PHILIPSFortimo FastFlex 2x2 DA UHE
A lengthB heightC foot
50.0(mm)7.0(mm)50.0(mm)
Normalized Intensity
Viewing angle (deg.)

AVIKA2X25050LN1R with PHILIPS Fortimo FastFlex LED 2x2 DA G5

Measured results
Beam angle @50% (Deg.) Major axis or Narrow Pos.Beam angle @50% (Deg.) Major axis or Wide Pos.Beam angle @10% (Deg.) Major axis or Narrow Pos.Beam angle @10% (Deg.) Major axis or Wide Pos.Efficacy (cd/lm) Major axis or Narrow Pos.Efficacy (cd/lm) Minor axis or Wide Pos.
0.3
https://www.optic-gaggione.com/wp-content/uploads/led_manufacturer_logo/PHILIPS/PHILIPS.jpeg
PHILIPSFortimo FastFlex LED 2x2 DA G5
A lengthB heightC foot
50.0(mm)7.0(mm)50.0(mm)
Normalized Intensity
Viewing angle (deg.)
GAGGIONE S.A.S DOCUMENTS AND DATA All data provided in our datasheets, mechanical drawing and all other downloadable documents on our website www.optic-gaggione.com  are subject to change at any time without prior notice. GAGGIONE S.A.S. do not guarantee any of its own document nowhere else than on its own websites. As a consequence, all GAGGIONE S.A.S. documents that are downloadable on distributors, partners or other third-party websites or mobile applications are NOT guaranteed by GAGGIONE S.A.S. All data provided in our documents are based on our own measurements and evaluation and performed in-house in our optical laboratory, or in a certified third-party laboratory. Also, all data, even simulated data, are provided for reference and design purpose only. All data may change at any time if GAGGIONE S.A.S. improves its products/services or improves its own laboratory equipment. GAGGIONE S.A.S. is not responsible for the final use conditions and takes no responsibility under certain use conditions, out of the material specification (PMMA, PC, Silicone, any other material used in our products). USE OF CHEMICAL AGENTS FOR CLEANING OR ANY OTHER PURPOSES GAGGIONE S.A.S. recommends only the use of an optical duster along with purified water. Any other product containing chemical agents, especially alcohol or glue, may damage the mechanical or photometrical properties of the product. This applies for direct contact with the product or nearby chemical agents vapors or drops. Always wear clean gloves not to alter the product’s optical performances. GAGGIONE S.A.S. recommends the user to test its products in both prototypes and series assembly conditions in the end-fixture.